PAQUETES  > YCY14

 
    All units shall be factory assembled, piped, internally wired and fully charged with R-22. All units shall be designed to operate at outdoor ambient temperatures as high as 115° F. Cooling capacities shall be rated in accordance with A.R.I. standards. The YCY-G heating/cooling unit design is UL listed, specifically for outdoor applications using propane or natural gas. All units shall be designed for outdoor rooftop or ground level installation. Shipped for horizontal application, convertible to downflow.
  Casings

All panels shall be phosphatized, zinc-coated steel and weather-resistant powder paint., gasketed and insulated. Foil-faced glass fiber insulation shall be in the heat exchanger section and the evaporator section. Base pan shall be zinc-coated, heavy gauge, galvanized steel.

Weatherguard™ exterior corrosion resistant screws shall be used for added resistance to rust and corrosion.

Controls

Refrigeration cycle controls shall include condenser fan, evaporator fan and compressor contactors. Compressors shall be equipped with a combination internal winding thermostat/current overload. Internal high pressure relief shall also be provided.

Refrigeration System

Compressors — All units shall have hermetically sealed Climatuff® compressors. Compressors shall be equipped with over temperature, over current and high pressure protection

Evaporator Coil — Internally enhanced 3/8-inch OD seamless copper tubing mechanically bonded to aluminum fins, factory pressure and leak tested at 250 to 300 psig.

Condenser Coil — Outdoor coils shall be internally enhanced 3/8-inch OD seamless copper tubing mechanically bonded to aluminum fins. Each coil shall be factory pressure and leak tested at 420 psig. Indoor Fan — Direct-drive, forward-curved, centrifugal type. Motor shall have thermal overload protection. Permanently lubricated motor bearings. Motor/blower assembly isolated from unit with rubber mounts.

Outdoor Fan — Direct-drive, draw thru, vertical discharge propeller type. Weatherproofed permanent split capacitor fan motor shall have built-in thermal overload and permanently lubricated motor bearings.

Low Ambient — Standard refrigerant system operation down to 55° F Low ambient accessory required for operation in 0° F ambient condition.
  FICHA TÉCNICA
PAQUETES
   
 

2 A 5 TR

WCC3
YCC3
TCC3
TCC10
TCY14
WCC10
WCY14
WCZ16
YCC10
YCY14
YCZ16
 

6 A 10 TR

IOM
TSC
WSC
YSC
 

12 A 25 TR

IOM
TC / YC
WC
 

20 A 130 TR

S-HF
TC-TE-YC

VENTILACIÓN | Hábitat | Comercial | Industrial  :: AIRE ACONDICIONADO | Mini-Split | Paquetes | Divididos | Chilers |
MG Asociados, Expertos en ventilación