CHILERS  > CGAF

 
    Design and manufacturing excellence makes Trane a leader in the air-cooled chiller marketplace. For over 40 years, Trane has been using the best engineering available in development, manufacturing, and marketing to produce quality products.

This tradition of using excellence to meet market demands is illustrated with the Trane 10 through 60-ton air-cooled chillers.

  Units shall be assembled on heavy gauge steel mounting/lifting rails and shall be weatherproofed. Units shall include hermetic scroll compressors, plate fin condenser coil, fan(s) and motor(s), controls and complete factory installed operating charge of oil and R-22 refrigerant. Operating range shall be between 115°F and 0°F. Units shall be either UL or CSA certified and rated in accordance with ARI Standard 550/590-98.

Casing

Unit casing shall be constructed of 18- gauge zinc coated heavy gauge, galvanized steel. Exterior surfaces shall be cleaned, phosphatized and finished with a weather-resistant baked enamel finish. Units surface shall be tested to withstand a 500 consecutive hour salt spray durability test. Units shall have removable panels which allow access to major components and controls.

Refrigeration System

Unit shall have two separate and independent refrigeration circuits. Each refrigeration circuit shall have integral subcooling circuits. Refrigeration filter driers and sightglasses shall be provided as standard.

Compressors

Unit shall have two Trane direct-drive hermetic scroll compressors with centrifugal oil pump and provide positive lubrication to all moving parts.

Motor shall be suction gas-cooled and shall have a voltage utilization range of plus or minus 10 percent of nameplate voltage. Crankcase heater, internal temperature and current-sensitive motor overloads shall be included for maximum protection. External high and low pressure cutout devices shall be provided.

Condenser Coil

Coils shall be 3/8” copper tubes mechanically bonded to configured aluminum plate fin as standard. Factory pressure and leak tested to 420 psig minimum air pressure and design working pressure shall be 376 psig.

Metal grilles with PVC coating for coil protection are optional.